Home > Products > Power Distribution > PDM30
PDM30

General Features
- Each output is over-current, short circuit and thermal overload protected
- Outputs programmable in 1 A steps
- Outputs controllable via a combination of switch inputs, CAN messages and logic functions
- Switch inputs ranging from 0 to 51 V, resolution 0.2 V
- Performing up to 200 logic operations using operators like Flash, Pulse, Set/Reset, Hysteresis, Toggle, And, Or, Less than, Greater than, Not equal to, Equal to, True, False etc.
- Performing functions such as flashing indicator lights and controlling thermofan and fuel pump
- Using logic functions to selectively turn off systems during low battery voltage or engine starting, reducing drain on the battery
- Providing full diagnostic information, including output currents and voltages, input voltages, and error status
- Transmitting diagnostic information via CAN to a display or data logging device or monitoring directly on a PC
Useful links
Find out more about MoTeC's new CAN Keypads