The MoTeC Logo
Welcome
Products
Downloads
Training
Forum
FAQ
Careers
Dealers
Products
The MoTeC Logo
Welcome Products Downloads Training Forum FAQ Careers Dealers
The MoTeC Logo
C12X Input Loom
C12X Input Loom
C12X Input Loom
Part No: #61259

OVERVIEW

The C125 Input Loom is an optional accessory that easily adds 6 analogue voltage inputs and 2 analogue temperature inputs to your C125 terminated loom.

The loom has been made so that it is simple to install, with minimal wiring required. Each of the eight 2.5 metre leads is individually twisted and heat shrunk for a professional finish.

To use this loom, the C125 requires the C125 I/O upgrade (29600).

SPECIFICATIONS

  • 6 analogue voltage input leads
  • 2 analogue temperature input leads
  • Lead lengths are 2.5 metre with individually labelled ends
  • 22 gauge Teflon coated Raychem light weight wire
  • High temperature heat shrink
  • Terminated connections designed to plug straight into the CDL3 terminated loom
  • Terminated pins designed to be pushed straight into the 34 pin connector on the C125 terminated loom.

INSTALLATION

  1. Connect the DTM 4 pin male of the Input loom to the GPS DTM 4 pin female connector of the C125 loom. The purpose of this connection is to supply 5 V and 0 V to the sensors.
  2. Connect the DTM 4 pin female connector of the Input loom to the GPS connector.
  3. Remove the 34 pin C125 connector from the back of the C125.
  4. Unlock the 34 pin CDL3 connector by pushing in the long white locking tab.
  5. Remove the white plugs from pins 3, 4 ,5, 6, 12, 13, 16 and 17.
  6. Insert pinned wires into the 34 pin C125 connector as follows:
    • AV1 – blue wire into pin location 3
    • AV2 – green wire into pin location 4
    • AV3 – violet wire into pin location 5
    • AV4 – gray wire into pin location 6
    • AV5 – yellow wire into pin location 12
    • AV6 – white wire into pin location 13
    • AT1 – brown wire into pin location 16
    • AT2 – orange wire into pin location 17
  7. Secure the pins in place by pushing in the two white locking tabs on the 34 pin C125 connector. If the two locking tabs are difficult to push back, it is an indication that one or more of the inserted pins is not seated correctly.
  8. Run the AV and AT wires to the locations required for your new sensors.

WIRING

Note the following:

  • The red wires are 5 V
  • The black wires are 0 V
  • Coloured wires are the AV and AT wires.
  • Shorten the looms as required by cutting them to length
  • Loop and secure un-used looms for future use.

PURCHASING

If you are interested in purchasing this product contact an Authorised MoTeC Dealer.

DOWNLOADS

Useful Links

This page shows the relevant downloads for this product. For a full selection of MoTeCs downloads visit the Downloads page.

 

To keep up-to-date with the latest webinars or software you can subscribe to our mailing lists and we will send you a message when new items are released.

To sign-up for a mailing list click the "SIGN-UP: WEBINAR NEWS" or "SIGN-UP: SOFTWARE RELEASE" button below.

OVERVIEW

SPECIFICATIONS

INSTALLATION

WIRING

PURCHASING

DOWNLOADS