OVERVIEW

The TCA Thermocouple Amplifier provides cold junction compensation and amplification of a thermocouples micro volt output into an accurate 0 to 5 V signal.

SPECIFICATIONS

Cold Junction Compensation

  • Cold junction compensation is performed at the thermocouple connector.The thermocouple must be connected using K Type Thermocouple wire or K Type compensating wire all the way to the amplifiers connector (there must be no copper wire in-between).

Input characteristics

  • Common mode voltage range: - 5V to + 2.5V
  • Input impedance: Negative input 100 kΩ to 0V
  • Input impedance: Positive input > 1 MΩ to 0V

Output characteristics

  • Normal operation:
    • Maximum sink current: 5mA (0 to 5V output)
    • Maximum source current: 5mA (0 to 4.2V output), 2mA (4.2 to 5V output)
  • Absolute Maximum:
    • Output sink current: 5mA max
    • Output source current: current limited, protected against continuous short to 0V
    • Applied output voltage: 0V, 5.0Vmax. voltages outside these limits may cause damage
    • Driven output voltage: - 0.3Vmin, 5.3Vmax. (no load)

Power Supply

  • Supply current: 1mA typical (plus output drive current)
  • Supply voltage:
    • Recommended voltage: 8V regulated
    • Operational voltage range: 7.5VDC min, 22VDC max
    • If connected to a 12V vehicle battery then the connection should be made near a device that includes transient voltage clamping of 60V or less
    • Maximum reverse voltage: - 20V
    • Max transient supply voltage: 60V for < 100ms at < 1% duty

Accuracy

  • Conditions: 25°C ambient and 25°C measured
  • Calibration error: ± 3°C
  • Gain error: ± 0.5% max
  • Temp drift: ± 0.05 °C / °C max (over 0 to 50°C ambient)
  • Total errors:
    • (Calibration + Gain + Temp drift) for 0°C to 50°C ambient
    • At measured temp of 25°C, Total error ± 4.25°C
    • At measured temp of 1000°C, Total error ± 9.25°C

Operating temperature

  • Operating Temp Range: – 10°C to 80°C ambient

Ingress Protection (IP) Rating

  • Environmental protection: IP53 (with connector facing down)

CALIBRATION

Because thermocouples have nonlinear characteristics it is best to use a calibration table to relate the output voltage and temperature. The following table should be used.

Using a linear calibration rather than a calibration table can result in errors of up to 20°C.
Temp°C Temp°F Nominal output voltage
0 32 0.000
50 122 0.196
100 212 0.397
200 392 0.788
300 572 1.183
400 752 1.589
500 932 2.000
600 1112 2.413
700 1292 2.822
800 1472 3.225
900 1652 3.617
1000 1832 4.000
1100 2012 4.371
1200 2192 4.731
1250 2282 4.906

PINOUT

3 Pin Connector

Mating connector # 68052

Pin Colour Name
1 Black 0V
2 White Signal output
3 Red 8V
To avoid inaccurate readings the 0 V Pin of the amplifier should be connected to the 0 V rail of the voltage supply device. Do Not connect to chassis ground.

PURCHASING

If you are interested in purchasing this product contact an Authorised MoTeC Dealer.

DOWNLOADS

Temperature Sensors
Name
Version / Part
Published
Download
Name, Version / Part, Published
Name
Version / Part
Published
Download
TCA Thermocouple Amplifier - Product Specification
58008
Jun 2004
Download
TCA Thermocouple Amplifier - Product Specification
58008
Jun 2004
TCA Thermocouple Amplifier - Product Specification
58008
Jun 2004
Download
TCA Thermocouple Amplifier A03 - Wiring Diagram
58008
Jul 2004
Download
TCA Thermocouple Amplifier A03 - Wiring Diagram
58008
Jul 2004
TCA Thermocouple Amplifier A03 - Wiring Diagram
58008
Jul 2004
Download
Useful Links

This page shows the relevant downloads for this product. For a full selection of MoTeCs downloads visit the Downloads page.

 

To keep up-to-date with the latest webinars or software you can subscribe to our mailing lists and we will send you a message when new items are released.

To sign-up for a mailing list click the "SIGN-UP: WEBINAR NEWS" or "SIGN-UP: SOFTWARE RELEASE" button below.

OVERVIEW

SPECIFICATIONS

CALIBRATION

PINOUT

PURCHASING

DOWNLOADS