The MoTeC Logo
Welcome
Products
Downloads
Training
Forum
FAQ
Careers
Dealers
Products
The MoTeC Logo
Welcome Products Downloads Training Forum FAQ Careers Dealers
The MoTeC Logo
L120 (USB)
L120 (USB)
L120 (USB)
Part No: #18045

OVERVIEW

The L120 Enclosed Logger (USB) is a powerful control device and fully programmable data logger, all in one compact unit.

It comes standard with 120MB internal memory plus USB logging for additional data capacity, convenience and flexibility.

The L120 acquires data from other devices, such as an ECU, for logging and telemetry. It can be used in a wide range of applications, either as a standalone unit or integrated with other electronic devices such as displays and PDM's.

Note: An L120 Enclosed Logger without USB Logging is also available. (Part #18039)

FEATURES

  • Suitable for bikes, cars, marine and industrial applications
  • USB Logging
  • 120MB internal logging memory
  • GPS Lap Timing
  • Supports Wideband Lambda from MoTeC PLMs or LTCs
  • Easily integrates with MoTeC CAN based products such as ECUs and expanders
  • Full I/O expansion available with use of E888, E816 expanders

ACCESSORIES

  • 62204 – L120 LOOM
  • 61259 – L120 INPUT LOOM
  • 61279 – CABLE USB LOGGING 1.5M (PANEL MOUNT)
  • 61403 – CABLE, AUTOSPORT USB LOGGING 1.5M (PANEL MOUNT)
  • 61280 –
  • 61292 – 32 GB USB3 FLASH DRIVE

OPTIONAL UPGRADES

  • 29624 – L120 T2 TELEMETRY
  • 29621 – L120 PRO ANALYSIS
  • 29601 – L120 I/O

SPECIFICATIONS

Communications
  • 2 x configurable CAN buses, with individually programmable CAN bus speeds.
    • One can be used as RS232 Receive
  • 2 x dedicated RS232 ports
    • One with Transmit and Receive
    • One with Receive only
Inputs

(* available via I/O upgrade)

  • 2 x digital inputs
  • 3 x speed inputs
  • 6* x analogue voltage inputs:
    • 4* x 0 to 5.46 V, 1.33 mV resolution
    • 2* x 0 to 15.0 V, 3.66 mV resolution
  • 2* x analogue temperature inputs, 0 to 15 V, 3.66 mV resolution
Outputs

(* available via I/O upgrade)

  • 4* x low side outputs PWM or switched operation
    • 0.5 A maximum, current limited and thermal overload protected
Logging

(available via upgrades)

  • 120 MB internal logging memory
  • USB logging to a removable storage device
  • Logging rates up to 500 samples per second
  • Fast Ethernet download
Internal Sensors
  • 3-axis accelerometer, detection range: +/- 5G
  • Sensor supply voltage
  • Battery voltage
Power supply
  • Operating voltage: 6 to 32 V DC
  • Operating current: 0.5 A typical at 14 V (excl. sensor currents)
  • Reverse battery protection
  • Battery transient protection
Sensor supply currents
  • 5 V sensor supply: 0.25 A maximum
  • 8 V sensor supply: 0.25 A maximum
Operating temperature
  • Internal: -20 °C to 70 °C
  • Typical ambient temperature range in free air: -20 °C to 55 °C
Physical
  • Unit size: 134.5 x 103.9 x 20.2 mm excluding connector
  • Weight 310 g
  • 1 x 34 pin waterproof connector
  • 1 x mini USB port (type B)
  • The device is rated to IP67

    IP rating is dependant upon the user ensuring that the connector entries are waterproof, which, as a minimum, requires all unused wire cavities on the connector to be plugged.

COMPATIBILITY

  • MoTeC ECUs: All models (some earlier models may require an additional adaptor in conjunction with the RS232 adaptor)
  • MoTeC Displays/Loggers: All
  • MoTeC Expanders: E816 and, E888 expanders.
  • MoTeC Accessories: SLM, PLM, LTC, BR2, PDM, GPS, ADR2, V2 etc.
  • Many non-MoTeC devices

SOFTWARE

  • Microsoft Windows based software
  • Used for setup and management of the data logging system, providing:
    • Configuration of the inputs, ouputs, data logging and calculations.
    • Offline generation of a configuration file that can then be sent to the device.
    • Channel monitoring
    • Firmware updating and extensive help screens
  • i2 Data Analysis software provides the tools for comprehensive data analysis. Standard or Pro* version available
  • T2 Telemetry* software

(* available via upgrades)

ETHERNET WIRING

ECU WIRING

When using an M4, M48 or M8 ECU, the L120 should be connected via RS232. For some ECUs, a PCI cable may also be required.

The Display Logger should be connected via the CAN bus when using an M1 or ‘hundred series’ ECU(M400/M600/M800/M880) or M84, and any number of other CAN devices. Example:

Detailed wiring information is available in the help topics of the C125 Dash Manager software at https://www.motec.com.au/downloads

DIMENSIONS AND MOUNTING

Measurements in mm.

Note: Do not remove any part of the casing. The case provides electromagnetic screening to avoid interference with other equipment, and is also essential for thermal management. Thermal management may be compromised if mounted in a confined space, refer to the operating temperature specifications. Ensure product is not stressed when mounted.

PINOUT

Mating Connector: Part number 65044

Pin Name Standard Function Optional Function (with I/O upgrade)
1 E-TX– Ethernet Transmit –
2 E-TX+ Ethernet Transmit +
3 AV1 Analogue Voltage Input 1
4 AV2 Analogue Voltage Input 2
5 AV3 Analogue Voltage Input 3
6 AV4 Analogue Voltage Input 4
7 8V Sensor 8 V
8 5V Sensor 5 V
9 0V Sensor 0 V
10 E-RX– Ethernet Receive –
11 E-RX+ Ethernet Receive +
12 AV5 Analogue Voltage Input 5
13 AV6 Analogue Voltage Input 6
14 DIG1 Digital Input 1
15 DIG2 Digital Input 2
16 AT1 Analogue Temp Input 1
17 AT2 Analogue Temp Input 2
18 CAN1L CAN1 Lo
19 CAN1H CAN1 Hi
20 RS232-1 TX RS232-1 Transmit Output
21 SPD1 Speed Input 1
22 SPD2 Speed Input 2
23 SPD3 Speed Input 3
24 Not used Not used
25 RS232-2 RX RS232-2 Receive Input
26 CAN2L CAN2 Lo / RS232 Ground Input
27 CAN2H CAN2 Hi / RS232 Receive Input
28 RS232-1 RX RS232-1 Receive Input
29 AUX1 Auxiliary Output 1
30 AUX2 Auxiliary Output 2
31 AUX3 Auxiliary Output 3
32 AUX4 Auxiliary Output 4
33 BAT+ Battery Positive
34 BAT– Battery Negative

PURCHASING

If you are interested in purchasing this product contact an Authorised MoTeC Dealer.

DOWNLOADS

Useful Links

This page shows the relevant downloads for this product. For a full selection of MoTeCs downloads visit the Downloads page.

 

To keep up-to-date with the latest webinars or software you can subscribe to our mailing lists and we will send you a message when new items are released.

To sign-up for a mailing list click the "SIGN-UP: WEBINAR NEWS" or "SIGN-UP: SOFTWARE RELEASE" button below.

OVERVIEW

FEATURES

ACCESSORIES

OPTIONAL UPGRADES

SPECIFICATIONS

COMPATIBILITY

SOFTWARE

ETHERNET WIRING

ECU WIRING

DIMENSIONS AND MOUNTING

PINOUT

PURCHASING

DOWNLOADS